Emergency & Exit Light Inspection Checklist — NFPA 101
Emergency lighting and exit sign inspection checklist per NFPA 101. Covers 30-second monthly functional tests and 90-minute annual battery tests.
NFPA 101Emergency/Exit Light1-2 min per unit (monthly) / 90+ min per unit (annual)27 inspection items
Unit Identification
- CheckboxRecord unit location (floor, room, hallway, stairwell)
- CheckboxIdentify unit type (emergency light, exit sign, combo unit)
- CheckboxRecord manufacturer and model number
- CheckboxNote battery type (sealed lead-acid, nickel-cadmium, lithium)
- CheckboxDocument unit age and last battery replacement date
Monthly 30-Second Test
- CheckboxActivate test button to simulate power failure
- CheckboxVerify all lamps illuminate within 10 seconds
- CheckboxConfirm illumination level appears adequate
- CheckboxHold test for minimum 30 seconds
- CheckboxVerify unit returns to normal charging mode after test
- CheckboxCheck charging indicator light is illuminated
Annual 90-Minute Test
- CheckboxDisconnect unit from normal power source
- CheckboxStart timer for 90-minute discharge test
- CheckboxVerify all lamps remain illuminated for full 90 minutes
- CheckboxRecord illumination levels at start and end of test
- CheckboxConfirm unit maintains minimum required illumination throughout test
- CheckboxReconnect power and verify unit recharges properly
- CheckboxNote any dimming or flickering during the 90-minute period
Physical Condition
- CheckboxInspect housing for cracks, damage, or discoloration
- CheckboxVerify mounting is secure and not loose
- CheckboxCheck lamp heads are properly aimed at walking surfaces
- CheckboxConfirm exit sign face is clean and legible from required distance
- CheckboxVerify directional arrows on exit signs are correct for the path of egress
Battery Condition
- CheckboxCheck for signs of battery leakage or swelling
- CheckboxVerify battery connections are clean and tight
- CheckboxRecord battery voltage if accessible
- CheckboxFlag units that failed 90-minute test for battery replacement
Use This Checklist Digitally in KomplyOS
Complete inspections on your phone, capture photos, collect signatures, and generate professional reports automatically.
Contact UsRelated Templates
NYC DOB / ASME
Boiler Inspection Checklist
Comprehensive annual boiler inspection checklist covering safety controls, combustion systems, pressure vessels, and operating conditions per NYC DOB requirements.
29 items45-90 min
NFPA 72 / FDNY
Fire Alarm System Inspection Checklist
Annual fire alarm inspection checklist covering initiating devices, notification appliances, control panels, and communication links per NFPA 72 and FDNY requirements.
32 items2-6 hours
NFPA 25
Sprinkler System Inspection Checklist (NFPA 25)
Quarterly and annual sprinkler system inspection checklist covering control valves, water supply, sprinkler heads, piping, and flow testing per NFPA 25.
30 items2-8 hours